The vulnerabilities are not dependent on one another. Exploitation of one of the vulnerabilities is not required to exploit another vulnerability. In addition, a software release that is affected by one of the vulnerabilities may not be affected by the other vulnerabilities.
Details about the vulnerabilities are as follows:
CVE-2025-20169, CVE-2025-20170, CVE-2025-20171, CVE-2025-20173, CVE-2025-20174, CVE-2025-20175, CVE-2025-20176: Cisco IOS and IOS XE Software SNMP Software Denial of Service Vulnerabilities
Multiple vulnerabilities in the SNMP subsystem of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device.
These vulnerabilities are due to improper error handling when parsing SNMP requests. An attacker could exploit these vulnerabilities by sending a crafted SNMP request to an affected device. A successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition.
These vulnerabilities affect SNMP versions 1, 2c, and 3. To exploit these vulnerabilities through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit these vulnerabilities through SNMP v3, the attacker must have valid SNMP user credentials for the affected system.
Cisco plans to release software updates that address these vulnerabilities. There are no workarounds that address these vulnerabilities. There are mitigations that address these vulnerabilities.
Bug ID(s): CSCwm79581, CSCwm79554, CSCwm79564, CSCwm79590, CSCwm79570, CSCwm79596, CSCwm79577
CVE ID(s): CVE-2025-20169, CVE-2025-20170, CVE-2025-20171, CVE-2025-20173, CVE-2025-20174, CVE-2025-20175, CVE-2025-20176
Security Impact Rating (SIR): High
CVSS Base Score: 7.7
CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H
CVE-2025-20172: Cisco IOS, IOS XE, and IOS XR Software SNMP Denial of Service Vulnerabilities
A vulnerability in the SNMP subsystem of Cisco IOS Software, Cisco IOS XE Software, and Cisco IOS XR Software could allow an authenticated, remote attacker to cause a DoS condition on an affected device.
This vulnerability is due to improper error handling when parsing SNMP requests. An attacker could exploit this vulnerability by sending a crafted SNMP request to an affected device. For Cisco IOS and IOS XE Software, a successful exploit could allow the attacker to cause the device to reload unexpectedly, resulting in a DoS condition. For Cisco IOS XR Software, a successful exploit could allow the attacker to cause the SNMP process to restart, resulting in an interrupted SNMP response from an affected device. Devices that are running Cisco IOS XR Software will not reload.
This vulnerability affects SNMP versions 1, 2c, and 3. To exploit this vulnerability through SNMP v2c or earlier, the attacker must know a valid read-write or read-only SNMP community string for the affected system. To exploit this vulnerability through SNMP v3, the attacker must have valid SNMP user credentials for the affected system.
Cisco plans to release software updates that address these vulnerabilities. There are no workarounds that address these vulnerabilities. There are mitigations that address these vulnerabilities.
Cisco IOS and IOS XE Software
Bug ID(s): CCSCwm89600
CVE ID(s): CVE-2025-20172
Security Impact Rating (SIR): High
CVSS Base Score: 7.7
CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H
Cisco IOS XR Software
Bug ID(s): CSCwn08493
CVE ID(s): CVE-2025-20172
Security Impact Rating (SIR): Medium
CVSS Base Score: 4.3
CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L